Treatment of cadmium (Cd), cyanide (CN) and cadmium-cyanide (Cd-CN) wastewater solutions by electrocoagulation (EC) using iron electrodes have been investigated in this research. CN and Cd removals at current density of 30 A/m2 and EC time of 50 min from Cd-CN containing wastewaters were 99.70 and 99.52, respectively; and 2.1746 /m3 at operation cost at these EC conditions. EC gives CN removal efficiency of 99.81 and 2.5978 /m3 operation cost for wastewater contaminated only by CN with 30 A/ m2 and 50 min of process time. For wastewaters contaminated only by Cd, 99.8 removal efficiency, with 2.052 /m3 operation cost under the same current density and process time. Approximately the same high removal efficiencies were achieved for each of the wastewater (Cd-CN, CN, Cd) used in the experiments. The highest removal efficiency of CN was achieved at pH 8.6 for wastewaters contaminated by CN or CN-Cd whereas the highest Cd removal efficiency was obtained at pH 10.6 for wastewaters contaminated by Cd. As a result, EC process gives quite high removal efficincies of Cd and CN for wastewaters coming from metal plating rinse baths.
Keyword: Cadmium and cyanide removal, Electrocoagulation, Operating cost
Yayın Adı (dc.title) | Cadmium, Cyanide and Cadmium-Cyanide Removal from Wastewater Solutions by Electrocoagulation Process |
Yazar/lar (dc.contributor.yazarlar) | Feride Ulu, Mehmet Kobya |
Yayın Türü (dc.type) | Makale |
Dil (dc.language) | İngilizce |
Yayımlanma Yılı (dc.date.issued) | 2020 |
Ulusal/Uluslararası (dc.identifier.ulusaluluslararasi) | Uluslararası |
Kaynak (dc.relation.journal) | 5th Eurasian Waste Management Symposium (EWMS) |
Kaynak Adı Ek Bilgi / Konferans Bilgisi (dc.identifier.kaynakadiekbilgi) | 5th Eurasian Waste Management Symposium (EWMS).- OCT 26-28, 2020.- Istanbul, TURKEY |
Sayfa (dc.identifier.startpage) | 88-94 |
Yayıncı (dc.publisher) | Oxford University Press |
Veri Tabanları (dc.contributor.veritaban) | Web of Science Core Collection |
Veri Tabanları (dc.contributor.veritaban) | Kaynak web sitesi |
İndex Türü (dc.identifier.index) | CPCI-S |
Özet (dc.description.abstract) | Treatment of cadmium (Cd), cyanide (CN) and cadmium-cyanide (Cd-CN) wastewater solutions by electrocoagulation (EC) using iron electrodes have been investigated in this research. CN and Cd removals at current density of 30 A/m2 and EC time of 50 min from Cd-CN containing wastewaters were 99.70 and 99.52, respectively; and 2.1746 /m3 at operation cost at these EC conditions. EC gives CN removal efficiency of 99.81 and 2.5978 /m3 operation cost for wastewater contaminated only by CN with 30 A/ m2 and 50 min of process time. For wastewaters contaminated only by Cd, 99.8 removal efficiency, with 2.052 /m3 operation cost under the same current density and process time. Approximately the same high removal efficiencies were achieved for each of the wastewater (Cd-CN, CN, Cd) used in the experiments. The highest removal efficiency of CN was achieved at pH 8.6 for wastewaters contaminated by CN or CN-Cd whereas the highest Cd removal efficiency was obtained at pH 10.6 for wastewaters contaminated by Cd. As a result, EC process gives quite high removal efficincies of Cd and CN for wastewaters coming from metal plating rinse baths. |
Özet (dc.description.abstract) | Keyword: Cadmium and cyanide removal, Electrocoagulation, Operating cost |
URL (dc.source.url) | https://eurasiasymposium.com/EWMS/files/Hall3/Session-1/191_Ulu-34.pdf |
Fakültesi / Enstitütü (dc.identifier.fakulte) | Mühendislik Fakültesi |
Bölümü (dc.identifier.bolum) | Çevre Mühendisliği Bölümü |
Kurumdaki Yazar/lar (dc.contributor.author) | Mehmet KOBYA |
Kayıt No (dc.identifier.kayitno) | BLDFFFED0C |
Kayıt Giriş Tarihi (dc.date.available) | 2024-09-04 |
Not (Yayımlanma Yılı) (dc.identifier.notyayinyili) | 2020 |
Wos No (dc.identifier.wos) | WOS:001254390200012 |
Konu Başlıkları (dc.subject) | cadmium and cyanide removal |
Konu Başlıkları (dc.subject) | electrocoagulation |
Konu Başlıkları (dc.subject) | operating cost |