Fabrication of an Electrochemical E. coli Biosensor in Biowells Using Bimetallic Nanoparticle-Labelled Antibodies

An electrochemical biosensor was developed for the determination of Escherichia coli (E. coli) in water. For this purpose, silver-gold core-shell (Ag@Au) bioconjugates and anti-E. coli modified PS-microwells were designed in a sandwich-type format in order to obtain higher sensitivity and selectivity. Ag@Au bimetallic nanoparticles were synthesized by co-reduction method. The core-shell formation was analyzed by using UV-Vis spectroscopy and transmission electron microscopy. Biotin labeled anti-E. coli antibodies were coupled with Ag@Au nanoparticles to form bioconjugates. The electrochemical immunosensor was prepared by immobilizing anti-E. coli on polystyrene (PS)-microwells via chemical bonding. These modified microwells were identified with X-ray photoelectron spectroscopy and surface enhanced Raman spectroscopy. E. coli was sandwiched between Ag@Au bioconjugates and anti-E. coli on PS-microwells at different concentrations. The relationship between the E. coli concentration and stripping current of gold ions (Au3+) were investigated by square wave anodic stripping voltammetry at pencil graphite electrode. The proposed method can provide some advantages such as lower detection limit and shorter detection time. The electrochemical response for the immunosensor was linear with the concentration of the E. coli in the range of 101 and 105 cfu/mL with a limit of detection 3 cfu/mL. The procedure maintains good sensitivity and repeatability and also offers utility in the fields of environmental monitoring and clinical diagnosis. -

Keywords: Bimetallic nanoparticles;E. coli;Anodic stripping voltammetry;Pencil graphite electrode

Görüntülenme
33
15.03.2016 tarihinden bu yana
İndirme
1
15.03.2016 tarihinden bu yana
Son Erişim Tarihi
28 Mayıs 2024 11:38
Google Kontrol
Tıklayınız
Tam metin
Detaylı Görünüm
Yayın Adı
(dc.title)
Fabrication of an Electrochemical E. coli Biosensor in Biowells Using Bimetallic Nanoparticle-Labelled Antibodies
Yazar/lar
(dc.contributor.yazarlar)
Haslet Eksi, Remziye Güzel, Burcu Güven, Ismail Hakki Boyaci, Ali Osman Solak
Yayın Türü
(dc.type)
Makale
Dil
(dc.language)
İngilizce
Yayımlanma Yılı
(dc.date.issued)
2015
Ulusal/Uluslararası
(dc.identifier.ulusaluluslararasi)
Uluslararası
Kaynak
(dc.relation.journal)
Electroanalysis
Süreli Sayı
(dc.identifier.issue)
2
Cilt/Sayı
(dc.identifier.volume)
27
Sayfa
(dc.identifier.startpage)
343–352
ISSN/ISBN
(dc.identifier.issn)
ISSN: 1040-0397; Online ISSN: 1521-4109
Yayıncı
(dc.publisher)
Wiley
Veri Tabanları
(dc.contributor.veritaban)
Web of Science Core Collection
Veri Tabanları
(dc.contributor.veritaban)
Wiley
Veri Tabanları
(dc.contributor.veritaban)
Scopus
İndex Türü
(dc.identifier.index)
SCI Expanded
İndex Türü
(dc.identifier.index)
Scopus
Etki Faktörü
(dc.identifier.etkifaktoru)
2,691 / 2018-WOS / 5 Year: 2,468
Özet
(dc.description.abstract)
An electrochemical biosensor was developed for the determination of Escherichia coli (E. coli) in water. For this purpose, silver-gold core-shell (Ag@Au) bioconjugates and anti-E. coli modified PS-microwells were designed in a sandwich-type format in order to obtain higher sensitivity and selectivity. Ag@Au bimetallic nanoparticles were synthesized by co-reduction method. The core-shell formation was analyzed by using UV-Vis spectroscopy and transmission electron microscopy. Biotin labeled anti-E. coli antibodies were coupled with Ag@Au nanoparticles to form bioconjugates. The electrochemical immunosensor was prepared by immobilizing anti-E. coli on polystyrene (PS)-microwells via chemical bonding. These modified microwells were identified with X-ray photoelectron spectroscopy and surface enhanced Raman spectroscopy. E. coli was sandwiched between Ag@Au bioconjugates and anti-E. coli on PS-microwells at different concentrations. The relationship between the E. coli concentration and stripping current of gold ions (Au3+) were investigated by square wave anodic stripping voltammetry at pencil graphite electrode. The proposed method can provide some advantages such as lower detection limit and shorter detection time. The electrochemical response for the immunosensor was linear with the concentration of the E. coli in the range of 101 and 105 cfu/mL with a limit of detection 3 cfu/mL. The procedure maintains good sensitivity and repeatability and also offers utility in the fields of environmental monitoring and clinical diagnosis. -
Özet
(dc.description.abstract)
Keywords: Bimetallic nanoparticles;E. coli;Anodic stripping voltammetry;Pencil graphite electrode
URL
(dc.rights)
http://onlinelibrary.wiley.com/doi/10.1002/elan.201400370/abstract
DOI
(dc.identifier.doi)
10.1002/elan.201400370
Fakültesi / Enstitütü
(dc.identifier.fakulte)
Mühendislik Fakültesi
Bölümü
(dc.identifier.bolum)
Kimya Mühendisliği Bölümü
Kurumdaki Yazar/lar
(dc.contributor.author)
Ali Osman SOLAK
Kayıt No
(dc.identifier.kayitno)
BL953A269B
Kayıt Giriş Tarihi
(dc.date.available)
2016-03-15
Not (Yayımlanma Yılı)
(dc.identifier.notyayinyili)
February 2015
Wos No
(dc.identifier.wos)
WOS:000349558900011
Konu Başlıkları
(dc.subject)
bimetallic nanoparticles
Konu Başlıkları
(dc.subject)
coli
Konu Başlıkları
(dc.subject)
anodic stripping voltammetry
Konu Başlıkları
(dc.subject)
pencil graphite electrode
Analizler
Yayın Görüntülenme
Yayın Görüntülenme
Erişilen Ülkeler
Erişilen şehirler
Yükümlülüklerimiz ve çerez politikamız T.C. 6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamındadır.
Tamam

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms