Harmonic Contribution Detection of Iron and Steel Plants Based on Correlation of Time-Synchronized Current and Voltage Signals

Özgül SALOR-DURNA

In this paper, the problem of detecting the harmonic responsibility of iron and steel (I&S) plants, which are supplied from a point of common coupling (PCC) is addressed. A new harmonic responsibility measure, which does not require the instantaneous impedance measurements, is proposed to present the amount of harmonic responsibility of each plant supplied from the PCC. The algorithm is based primarily on the correlation of voltage and current signals which are measured with a time-synchronized manner at the PCC. The proposed method is first verified using both synthetic data generated in PSCA ...More

Access to Files

Statistical Models of EAF Harmonics Developed for Harmonic Estimation Directly from Waveform Samples Using Deep Learning Framework

Özgül SALOR-DURNA

In this paper, a method to generate large amounts of Electric Arc Furnace (EAF) currents with harmonics simulating the actual EAF operation characteristics to be used with deep learning (DL) applications of harmonic estimation is investigated. For this purpose, the behavior of the EAF current harmonics is examined in statistical terms using the field data collected at a transformer substation supplying an EAF plant. Then, a significantly larger amount of EAF current data is generated using the statistics mimicking the real EAF behavior to train the DL-based harmonic estimator. The outcomes of ...More

Access to Files

Determination of Harmonic Current Responsibility at Point of Common Coupling of the Electrical System by Correlation of Voltage and Current Signals

Özgül SALOR-DURNA

In this study, the harmonic current responsibilites of the utility and the loads at the point of common coupling in the electrical system with the correlation analysis of measured current and voltage signals is discussed. Using the correlation coefficient obtained by correlation analysis, it is possible to determine who is responsible of which harmonic frequecy component, the loads or the utility. In PSCAD / EMTDC computer simulation, current and voltage signals obtained by preparing different circuit diagrams are processed in MATLAB environment and the accuracy of the simulation results are t ...More