In this research work, a new method which determines the individual harmonic voltage contributions of the EAF plants supplied from a point of common coupling (PCC) to the PCC voltage is presented. EAFs are one of the most significant sources of the harmonics, especially the uncharacteristic ones, therefore it is important to be able to discriminate the amount of individual contributions from the feeders of a PCC supplying multiple EAFs. The proposed method uses the relationship derived between the correlation coefficient of the PCC voltage and the feeder current waveforms and the harmonic volt ...More
In this research work, deep machine learning-based methods together with a novel data augmentation are developed for predicting flicker, voltage dip, harmonics, and interharmonics originating from highly time-varying electric arc furnace (EAF) currents and voltage. The aim with the prediction is to counteract both the response and reaction time delays of active power filters (APFs) specifically designed for electric arc furnaces (EAF). Multiple synchronous reference frame (MSRF) analysis is used to decompose the frequency components of the EAF current and voltage waveforms into dqo components. ...More
This paper proposes and implements, a harmonic analysis technique used in microgrids for inverter power control when measured voltage and current signals are passed over a communication link with considerable latency. Using frequency-shifting and filtering techniques, the measurement is converted to magnitude and phase information and passed over an asynchronous communication link to another controller, where the original waveform is recovered with delay compensation. The method allows accurate power calculations and grid synchronization over distributed prosumer controllers. The proposed meth ...More
In this research work, a new harmonic responsibility measure is proposed to extract the amount of harmonic responsibility of each plant supplied from the point of common coupling (PCC). The proposed method uses a function of the correlation coefficients between the voltage and current signals measured synchronously at the PCC. After the verification of the method on synthetic data generated in simulation environment, field data measurements of voltage and current are used to test the practicability of the proposed method. Harmonic contributions of the iron and steel (I&S) plants obtained using ...More