Advanced Search

Cancel
Found: 3 Piece 0.001 sn
- You can use the 'AND' / 'OR' / 'NOT' option for the things you want to add or remove.
- You can return to normal search by pressing the Cancel button.
Filters
Good health and well-beingEnsure healthy lives and promote well-being for all ages
Access to Files

Fabrication of an Electrochemical E. coli Biosensor in Biowells Using Bimetallic Nanoparticle-Labelled Antibodies

Ali Osman SOLAK

An electrochemical biosensor was developed for the determination of Escherichia coli (E. coli) in water. For this purpose, silver-gold core-shell (Ag@Au) bioconjugates and anti-E. coli modified PS-microwells were designed in a sandwich-type format in order to obtain higher sensitivity and selectivity. Ag@Au bimetallic nanoparticles were synthesized by co-reduction method. The core-shell formation was analyzed by using UV-Vis spectroscopy and transmission electron microscopy. Biotin labeled anti-E. coli antibodies were coupled with Ag@Au nanoparticles to form bioconjugates. The electrochemical ...More

Access to Files

Evaluation of Some Redox Mediators in the Design of Reagentless Amperometric Glucose Biosensor

Ali Osman SOLAK

The influence of redox mediators (tetrathiafulvalene (TTF), tetrathiafulvalene-tetracyanoquinodimethane complex (TTF-TCNQ), phenazine methosulfate (PMS), 5,6-diamino-1,10-phenonthroline (5,6-DAP), potassium ferrocyanide (K4[Fe(CN)6]), methylene blue (MB) and toluidine blue (TB)) on the response of amperometric glucose biosensor was investigated in this research. Graphite rod electrode (GRE) modified by adsorbed mediator and glucose oxidase (GOx) cross-linked with glutaraldehyde was served as working electrode. The highest amperometric signals were observed by using TTF and TTF-TCNQ as mediator ...More

Access to Files

Development of Nonenzymatic Benzoic Acid Detection on PdSn/GCE/Vulcan XC‐72R Prepared via Polyol Method

Nahit AKTAŞ

In this study a PdSn based sensor was developed for the determination of benzoic acid (BA) in foods. A carbon (Vulcan XC-72R) supported PdSn catalyst was prepared via polyol method and its surface electronic and chemical properties were investigated by advanced surface analytical techniques such as scanning electron microscopy (SEM), X-ray diffraction spectroscopy (XRD), X-ray Photoelectron Spectroscopy (XPS), temperature-programmed reduction with H-2 (TPR-H-2) and transmission electron microscopy (TEM). Electrochemical measurements were performed by employing cyclic voltammetry (CV) and diffe ...More

Our obligations and policy regarding cookies are subject to the TR Law on the Protection of Personal Data No. 6698.
OK

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms