Arsenic Removal by Electrocoagulation

Mehmet KOBYA

Because of the toxic impacts on human health, the arsenic (As) limit value in drinking water was decreased from 50 to 10 μg l −1 by the relevant authorities (WHO 1993; US EPA 2001). In this case, the problem of As pollution in natural water resources used for drinking water has grown even more and turned into a global crisis. According to reports in many parts of the world, over about 230 million people appear to be affected by high arsenic concentrations in groundwater. In this case, it turned out that there was a great need for cost-effective and environmentally friendly technologies from dr ...Daha fazlası

Erişime Açık

Removal of arsenic in groundwater from western Anatolia, Turkey using an electrocoagulation reactor with different types of iron anodes

Mehmet KOBYA | Mustafa DOLAZ

Electrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 mu g L-1, GW-2: 1132.1 mu g L-1, and GW-3: 52, 000 mu g L-1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 mu g L-1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As ...Daha fazlası

Erişime Açık

Arsenic removal from groundwater using an aerated electrocoagulation reactor with 3D Al electrodes in the presence of anions

Mehmet KOBYA

Co-occurrence of arsenic and anions in groundwater causes a severe health problems and combine effects of these pollutants significantly affect performance of treatment process. Thus, this study has been conducted to examine the combine effects of anions on arsenic removal using aerated electrocoagulation (EC) reactor with 3D Al electrodes in groundwater. A 3-level, six factors Box-Behnken experimental design (BBD) was applied to investigate the individual and combine effect of anions and operating time: phosphate (x(1): 1-10 mg L-1), silica (x(2): 20-80 mg L-1), bicarbonate (x(3): 130-670 mg ...Daha fazlası