Detaylı Arama

İptal
Bulunan: 3 Adet 0.001 sn
- Eklemek veya çıkarmak istediğiniz kriterleriniz için 'VE' / 'VEYA' /'DEĞİL' seçeneğini kullanabilirsiniz.
- İptal tuşuna basarak normal aramaya dönebilirsiniz.
Filtreler
Erişime Açık

Novel gallium-based voltammetric sensor for sensitive detection of cysteine

Nahit AKTAŞ

Carbon nanotube-supported gallium (Ga/CNT) was synthesized and characterized with energy dispersive X-ray scanning electron microscopy, temperature-programmed reduction, temperature-programmed oxidation, and temperature-programmed desorption methods. Characterization results revealed successful preparation of Ga/ CNT. Electrochemical measurements were performed by cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy. The Ga/CNT-based cysteine sensor had a linear response within the range of 0-200 mu M with current sensitivity of 0.0081 mu A/mu M (114 m ...Daha fazlası

Erişime Açık

Novel Cacao oil-based organo-hydrogels to detect carcinoma antigen 125 in serum medium; synthesis, characterization, and electrochemical measurements

Nahit AKTAŞ

In present study, cacao oil-based organo-hydrogels (OHCOs) are synthesized to detect carcinoma antigen 125 (CA-125) in serum medium with electrochemical methods such as cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV). OHCOs are prepared by the free radical polymerization reaction with agar, glycerol, and distinct ratios of cacao oil with glutaraldehyde (GA) crosslinker or methylene bisacrylamide (MBA) crosslinker. OHCOs are characterized via Fourier Transform Infrared Spec-troscopy (FT-IR), in different solvent environments and pH ...Daha fazlası

Erişime Açık

Novel 5-(2-phenylbenzo [b] thiophen-3-yl)furan-2-carbaldehyde based ovarian cancer carbohydrate antigen 125 electrochemical sensor

Hilal DEMİR KIVRAK

Herein, an electrochemical sensor based 5-(2-phenylbenzo [b] thiophen-3-yl)furan-2-carbaldehyde (PTFC) was developed for the detection of cancer antigen 125 (CA125). Measurements were obtained via cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV), and square wave voltammetry (SWV) techniques to investigate features of the electrochemical sensor such as concentration effect of CA125, incubation time, scan rate, limit of quantification (LOQ), limit of detection (LOD), and interference effect of structures found in serum. The sensor wa ...Daha fazlası

Yükümlülüklerimiz ve çerez politikamız T.C. 6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamındadır.
Tamam

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms